Use in the situation of tension running
◎ Output From 3W to 40w
◎ Suitable in the situation that objects must be rolled up
◎ Ability to use in the situation of tension running
◎ Output adjustment type is available
Standared Torque motor type
Item
Specifications
Insulation resistance
Use a DC500V high resistance gauge to measure the coil of motor and it's a outer shell when motor running in normal temperature and normal humidity, its value should be above 100MΩ .
Insulation pressure endurance
Apply 60Hz, 1.5kV at the coil of motor and it's a outer shell for one minute without and extraordinary phenomenon when motor running in normal temperature and normal humidity.
Temperature arise
Install two reduction gears or radiation plate of the same class at the motor. After rated running, test the coil by resistance method. Its value should be less than 75°C.
Insulation Class
Class B (130°C)
Overheat protection
6W is resist type others are sheetmetal type
Environment temperature
-10°C~+50°C
Humid around the environment
Below 85% (No frosting happen)
▲ Over heat shut down system is not a standard device, please notice before order.